The visit took place within the official trip of the management of the Russian Energy Agency (REA) to Kazan. The government of the Republic of Tatarstan and Russian Energy Agency signed a cooperation agreement which contemplates cooperation in the sphere of improvement of energy efficiency and innovative activities in...
read more
4.10.2011
According to the results of annual research by rating agency Expert RA, INVENT group is in the list of the largest Russian companies

read more

Arrangement of three-conductor polyvinylchloride sheathed cables which are flame-retardant if single

no-photo

 

1. Central filling made of bundle or copper wire in the center of sector cable core;

2. Round- or sector-shaped, stranded, compacted current-carrying conductor:

- metarial:

АПвВ, АПвБВ, АПвКВ, АПвКаВ, АПвКсВ – aluminum (А),
ПвВ, ПвБВ, ПвКВ, ПвКаВ, ПвКсВ – copper,

- section:

6 kV cables (round-shaped conductor) - 35-240 sq. mm
10, 20, 35 kV cables (round-shaped conductor) – 50–240 sq. mm
6, 10 kV cables (sector-shaped conductor) – 120–240 sq. mm;

3. Conductor screen made of extruded semiconducting cross-linked polyethylene;

4. Insulation made of cross-linked polyethylene (Пв);

5. Conductor screen made of extruded semiconducting cross-linked polyethylene;

6. Separating layer made of semiconducting crepe paper tape;

7. Screen made of copper wires connected by means of copper tape (for sector cables collective screen is applied over three insulated conductors)

- with section of minimum 16 sq. mm for cables with conductor section of 35-120 sq. mm,
- with section of minimum 25 sq. mm for cables with conductor section of 150-300 sq. mm,
- with section of minimum 35 sq. mm for cables with conductor section of over 300 sq. mm.

Note: Screen section is selected depending on short-circuit currents which shall be calculated according to field cable installation conditions. It is possible to manufacture cables with increased screen section.

8. Interphase filling made of rubber compound;

9. Inner sheath made of PVC compound (for armored cables);

10. Armor made of steel galvanized tapes (Б) or steel galvanized wires (K),
aluminum wires (Ka) or aluminum alloy wires (Kc).

11. Sheath made of PVC compound.