The visit took place within the official trip of the management of the Russian Energy Agency (REA) to Kazan. The government of the Republic of Tatarstan and Russian Energy Agency signed a cooperation agreement which contemplates cooperation in the sphere of improvement of energy efficiency and innovative activities in...
read more
4.10.2011
According to the results of annual research by rating agency Expert RA, INVENT group is in the list of the largest Russian companies

read more
PVC compound insulated power cables for stationary laying up to 3 kV inclusively
 NYM, 0,66; 1 kV, NYM-0,S07VV-R 0,66; 1 kV

NYM, 0,66; 1 kV

Power cables with copper conductors insulated by PVC and with PVC sheath.

NYM-0,S07VV-R 0,66; 1 kV

Power cables with copper conductors insulated by PVC and with PVC sheath with low flammability.

Construction:

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of PVC compound. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath is made of PVC compound and unvulcanized rubber compound, in NYM-0,S07VV-R cables - flame-resistant unvulcanized rubber compound with layer thickness of at least 0.1 mm, or of flame-resistant PVC compound.

5. Outer sheath is made of PVC compound, in NYM-0,S07VV-R cables - flame resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation. For power supply to electric plants which need cable glands at bushing.

NYM type cables are flame-retardant if single; NYM-0,S07VV-R type cables are flame-retardant if bunched.

 NAYY 0,66; 1 kV, NAYY-J 0,66; 1 kV

NAYY 0,66; 1 kV

Power cables with aluminum conductors insulated by PVC and with PVC sheath.

NAYY-J 0,66; 1 kV

Power cables with aluminum conductors insulated by PVC and with PVC sheath with low flammability.

Construction:

1. Current-carrying conductor – is made of aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC). Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three- and four conductor cables are twisted; two conductor cables have uniform conductors; three- and four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath is made of unvulcanized rubber compound, in NAYY-J cables - unvulcanized rubber compound or of flame-resistant PVC compound with layer thickness of at least 0.1 mm.

5. Outer sheath is made of PVC compound, in NAYY-J cables - flame resistant PVC compound.

Application

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation. For power supply to electric plants which need cable glands at bushing.

NAYY type cables are flame-retardant if single; NAYY-J type cables are flame-retardant if bunched.

 NYM 3 kV, NYM-0,S07VV-R 3 kV

NYM, 3 kV

Power cables with copper conductors insulated by PVC and with PVC sheath.

NYM-0,S07VV-R 3 kV

Power cables with copper conductors insulated by PVC and with PVC sheath with low flammability.

Construction:

1. Current-carrying conductor is made of copper, stranded conductor, round- or sector-shaped, of class 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC). Insulated cable conductors of have distinctive color.

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound, in NYM-0,S07VV-R cables - with flame resistant unvulcanized rubber compound.

5. Metal screen consists of two copper tapes or copper foil.

6. Outer sheath is made of PVC compound, in NYM-0,S07VV-R cables - flame resistant PVC compound.

Application

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation.

NYM type cables are flame-retardant if single. NYM-0,S07VV-R type cables are flame-retardant if bunched.

 NAYY 3 kV, NAYY-J 3 kV

NAYY 3 kV

Power cables with aluminum conductors insulated by PVC and with PVC sheath.

NAYY-J 3 kV

Power cables with aluminum conductors insulated by PVC and with PVC sheath with low flammability.

Construction:

1. Current-carrying conductor is made of aluminum, stranded conductor, round- or sector-shaped, of class 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC). Insulated cable conductors have distinctive color.

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound, in NAYY-J cables - with flame resistant unvulcanized rubber compound.

5. Metal screen consists of two copper tapes or copper foil.

6. Outer sheath is made of PVC compound, NAYY-J cables - flame resistant PVC compound.

Application

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation.

NAYY type cables are flame-retardant if single. NAYY-J type cables are flame-retardant if bunched.
 

 NYBY,NYRY 0,66; 1 kV, NYRGbY,NYFGbY 0,66; 1 kV

NYBY,NYRY 0,66; 1 kV

Power cables with copper conductors insulated by PVC, armored, jacketed by PVC.

NYRGbY,NYFGbY 0,66; 1 kV

Power cables with copper conductors insulated by PVC, armored, jacketed by PVC with low flammability.

CONSTRUCTION

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC).
Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath - in NYBY,NYRY cables is moulded out of the PVC compound or unvulcanized rubber compound; in NYRGbY,NYFGbY cables - flame resistant PVC compound or flame resistant unvulcanized rubber compound.

5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes, in this case cables are marked as NYBY,NYRY and NYRGbY,NYFGbY.

6. Jacket - in NYBY,NYRY cables is made of PVC compound, in NYRGbY,NYFGbY cables - flame resistant PVC compound.

APPLICATION
– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 kV and 1 kV with frequency of 50 Hz.
– For installation in ground (trenches), premises, tunnels, channels, mines (except for installation in blocks), and outdoors, with cable not subjected to significant tensile force, but if there is a mechanical damage risk during operation.

NYBY,NYRY type cables are flame-retardant if single. NYRGbY,NYFGbY type cables are flame-retardant if bunched. 

 

Contacts:

32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales  department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru

 

Обособленное подразделение г. Москва

Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Tel: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru
 

 

 NAYBY, NAYRY 0,66; 1 kV, NAYRGbY,NAYFGbY  0,66; 1 kV

NAYBY, NAYRY 0,66; 1 kV

Power cables with aluminum conductors insulated by PVC, armored, jacketed by PVC.

NAYRGbY,NAYFGbY  0,66; 1 kV

Power cables with aluminum conductors insulated by PVC, armored, jacketed by PVC with low flammability.

CONSTRUCTION

1. Current-carrying conductor is made of aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC).
Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath - in NAYBY, NAYRY cables is moulded out of the PVC compound or unvulcanized rubber compound; in NAYRGbY,NAYFGbY  cables - flame resistant PVC compound or flame resistant unvulcanized rubber compound.

5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes, in this case cables are marked as NAYBY, NAYRY  and NAYRGbY,NAYFGbY.

6. Jacket - in NAYBY, NAYRY  cables is made of PVC compound, in NAYRGbY,NAYFGbY  cables - flame resistant PVC compound

APPLICATION

– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 kV and 1 kV with frequency of 50 Hz.
– For installation in ground (trenches), premises, tunnels, channels, mines (except for installation in blocks), and outdoors, with cable not subjected to significant tensile force, but if there is a mechanical damage risk during operation.

NAYBY, NAYRY type cables are flame-retardant if single. NAYRGbY, NAYFGbY type cables are flame-retardant if bunched.

 NYBY,NYRY 3 kV, NYRGbY,NYFGbY 3 kV

NYBY,NYRY 3 kV

Power cables with copper conductors insulated by PVC, armored, jacketed by PVC.

NYRGbY,NYFGbY 3 kV

Power cables with copper conductors insulated by PVC, armored, jacketed by PVC with low flammability.

CONSTRUCTION

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC).
Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow). Insulation thickness is indicated in the Appendix.

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath - in NYBY,NYRY cables is moulded out of the PVC compound or unvulcanized rubber compound; in NYRGbY,NYFGbY cables - flame resistant PVC compound or flame resistant unvulcanized rubber compound.

5. Screen consists of copper tapes or copper foil.

6. Separating layer is made of PVC tapes.

7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

8. Jacket - in NYBY,NYRY cables is made of PVC compound, in NYRGbY,NYFGbY cables - flame resistant PVC compound

APPLICATION

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches), premises, tunnels, channels, mines (except for installation in blocks), and outdoors, with cable not subjected to significant tensile force, but if there is a mechanical damage risk during operation.

NYBY,NYRY type cables are flame-retardant if single. NYRGbY,NYFGbY type cables are flame-retardant if bunched.

 NAYBY, NAYRY  3 kV, NAYRGbY,NAYFGbY  3 kV

NAYBY, NAYRY  3 kV

Power cables with aluminum conductors insulated by PVC, armored, jacketed by PVC.

NAYRGbY,NAYFGbY  3 kV

Power cables with aluminum conductors insulated by PVC, armored, jacketed by PVC with low flammability.

CONSTRUCTION

1. Current-carrying conductor is made of aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of polyvinylchloride compound (PVC).
Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath - in NAYBY, NAYRY  cables is moulded out of the PVC compound or unvulcanized rubber compound; in NAYRGbY,NAYFGbY  cables - flame resistant PVC compound or flame resistant unvulcanized rubber compound.

5. Screen consists of copper tapes or copper foil.

6. Separating layer is made of PVC tapes.

7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

8. Jacket - in NAYBY, NAYRY cables is made of PVC compound, in NAYRGbY,NAYFGbY  cables - flame resistant PVC compound.

 NYCY 0,66; 1 kV, NAYCY 0,66; 1 kV

NYCY 0,66; 1 kV

Power cables with copper conductors insulated and sheathed by PVC with low fire hazard.

NAYCY 0,66; 1 kV

Power cables with aluminum conductors insulated and sheathed by PVC with low fire hazard

Construction:

1. Current-carrying conductor is made of copper (NYCY) or aluminum (NAYCY), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of flame-resistant polyvinylchloride composition. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors.

5. Outer sheath is made of flame-resistant PVC composition.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
–For industrial purposes and nuclear power stations when delivered to domestic market and for export.
–For operation in cable structures and spaces.

 NYCY 3 kV, NAYCY 3 kV

NYCY 3 kV

Power cables with copper conductors insulated and sheathed by PVC with low fire hazard.

NAYCY 3 kV

Power cables with aluminum conductors insulated and sheathed by PVC with low fire hazard

Construction:

1. Current-carrying conductor is made of copper (NYCY) or aluminum (NAYCY), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of flame-resistant polyvinylchloride composition. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors.

5. Metal screen consists of two copper tapes or copper foil.

6. Outer sheath is made of flame-resistant PVC composition.

Application

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For industrial purposes and nuclear power stations when delivered to domestic market and for export.
– For operation in cable structures and spaces.

  

 

Contacts:

32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales  department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
www.tatcable.ru
 

 

Обособленное подразделение г. Москва

Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Tel: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru

 

 NYBY, NYRY 0,66; 1 kV, NYRGbY,NYFGbY  0,66; 1 kV

NYBY, NYRY 0,66; 1 kV

Power cables with copper conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard.

NYRGbY,NYFGbY  0,66; 1 kV

Power cables with aluminum conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard.

Construction:

1. Current-carrying conductor is made of copper (NYBY, NYRY) or aluminum (NYRGbY,NYFGbY  ), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of flame-resistant polyvinylchloride composition. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors. Inner sheath thickness is indicated in the Appendix.

5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes, in this case cables are marked as NYBY, NYRY and NYRGbY,NYFGbY  .

6. Jacket is made of flame-resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For industrial purposes and nuclear power stations when delivered to domestic market and for export.
– For operation in cable structures and spaces.

Cables are designed for bunched installation.
 

 NYBY, NYRY 3 kV, NYRGbY,NYFGbY  3 kV

NYBY, NYRY 3 kV

Power cables with copper conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard.

NYRGbY,NYFGbY  3 kV

Power cables with aluminum conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard.

Construction:

1. Current-carrying conductor is made of copper (NYBY, NYRY) or aluminum (NYRGbY,NYFGbY  ), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of flame-resistant polyvinylchloride composition. Insulated conductors of multiconductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors.

5. Screen consists of two copper tapes or copper foil.

6. Separating layer is made of PVC tapes.

7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

8. Jacket is made of flame-resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For industrial purposes and nuclear power stations when delivered to domestic market and for export.
– For operation in cable structures and spaces.

Cables are designed for bunched installation.

 NYCY,NAYCY 0,66; 1 kV

NYCY,NAYCY 0,66; 1 kV

Power cables with copper conductors insulated and sheathed by PVC with low fire hazard, fire-resistant.

Construction:

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Thermal barrier is a lapping made of two micaceous tapes.

3. Insulation is made of flame-resistant polyvinylchloride compound. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).

5. Inner sheath is made of flame-resistant PVC compound.

6. Outer sheath is made of flame-resistant polyvinylchloride compound.

Application:

– For power and electric signals transmission and distribution in fixed electric plants at alternating voltage of 660 V and 1000 V with frequency of up to 100 Hz and direct voltage of 1000 V.
– For industrial purposes and nuclear power stations (NPS) outside the containment area in NPS systems class 2 when delivered to domestic market and for export, including to tropical countries.
– For installation in cable structures and spaces, including explosion-hazardous zones of all classes, except for B-1 class explosion-hazardous zones.

Cables are designed for bunched installation.

 NYCY,NAYCY 3kV

NYCY,NAYCY 3kV

Power cables with copper conductors insulated and sheathed by PVC with low fire hazard, fire-resistant.

Construction:

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Thermal barrier is a lapping made of two micaceous tapes.

3. Insulation is made of flame-resistant polyvinylchloride compound. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).

5. Inner sheath is made of flame-resistant PVC compound.

6. Metal screen consists of two copper tapes or copper foil.

7. Outer sheath is made of flame-resistant polyvinylchloride compound.

Application:
– For power and electric signals transmission and distribution in fixed electric plants at alternating voltage of 3 kV with frequency of up to 100 Hz.
– For industrial purposes and nuclear power stations (NPS) outside the containment area in NPS systems class 2 when delivered to domestic market and for export, including to tropical countries.
– For installation in cable structures and spaces, including explosion-hazardous zones of all classes, except for B-1 class explosion-hazardous zones.

Cables are designed for bunched installation.

 NYBY,NYRY,NYRGbY,NYFGbY  0,66; 1 kV

NYBY,NYRY,NYRGbY,NYFGbY  0,66; 1 kV

Power cables with copper conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard, fire-resistant.

Construction:

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Thermal barrier is a lapping made of two micaceous tapes.

3. Insulation is made of flame-resistant polyvinylchloride compound. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).

5. Inner sheath is made of flame-resistant PVC compound.

6. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

7. Outer sheath is made of flame-resistant polyvinylchloride compound.

Application:

– For power and electric signals transmission and distribution in fixed electric plants at alternating voltage of 660 V and 1000 V with frequency of up to 100 Hz.
– For industrial purposes and nuclear power stations (NPS) outside the containment area in NPS systems class 2 when delivered to domestic market and for export, including to tropical countries.
– For installation in cable structures and spaces, including explosion-hazardous zones of all classes, except for B-1 class explosion-hazardous zones.

Cables are designed for bunched installation.

 

 

 

 

Contacts:

32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales  department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
www.tatcable.ru

 

Обособленное подразделение г. Москва

Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Тел: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru

 

 NYBY,NYRY,NYRGbY,NYFGbY  3 kV

NYBY,NYRY,NYRGbY,NYFGbY  3 kV

Power cables with copper conductors insulated by PVC with low fire hazard, armored, jacketed by PVC with low fire hazard, fire-resistant.

Construction:

1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Thermal barrier is a lapping made of two micaceous tapes.

3. Insulation is made of flame-resistant polyvinylchloride compound. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).

5. Inner sheath is made of flame-resistant PVC compound.

6. Metal screen consists of two copper tapes or copper foil.

7. Separating layer is made of PVC tapes.

8. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

9. Outer sheath is made of flame-resistant polyvinylchloride compound.

Application:

– For power and electric signals transmission and distribution in fixed electric plants at alternating voltage of 3 kV with frequency of up to 100 Hz.
– For industrial purposes and nuclear power stations (NPS) outside the containment area in NPS systems class 2 when delivered to domestic market and for export, including to tropical countries.
– For installation in cable structures and spaces, including explosion-hazardous zones of all classes, except for B-1 class explosion-hazardous zones.

Cables are designed for bunched installation. 

 

Contacts:

32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales  department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
www.tatcable.ru

Обособленное подразделение г. Москва

Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Тел: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru