The visit took place within the official trip of the management of the Russian Energy Agency (REA) to Kazan. The government of the Republic of Tatarstan and Russian Energy Agency signed a cooperation agreement which contemplates cooperation in the sphere of improvement of energy efficiency and innovative activities in...
read more
4.10.2011
According to the results of annual research by rating agency Expert RA, INVENT group is in the list of the largest Russian companies

read more
XLPE insulated insulated power cables for stationary laying up to 3 kV inclusively
 N2XSY 0,66; 1kV, NA2XSY 0,66; 1kV

N2XSY 0,66; 1kV

Power cables with copper conductors, insulated by XLPE, sheathed by PVC with low flammability

NA2XSY 0,66; 1kV

Power cables with aluminum conductors, insulated by XLPE, sheathed by PVC with low flammability.

Construction:

1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated conductors  of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).

4. Inner sheath is made of flame-resistant unvulcanized rubber compound.

5. Outer sheath is made of flame-resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation. For power supply to electric plants which need cable glands at bushing.
– For cable lines bunched installation in cable structures, if there is no mechanical damage risk.

 N2XSY 3kV, NA2XSY 3kV

N2XSY 3kV

Power cables with copper conductors, insulated by XLPE, sheathed by PVC with low flammability

NA2XSY 3kV

Power cables with aluminum conductors, insulated by XLPE, sheathed by PVC with low flammability.

Construction:

1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant unvulcanized rubber compound.

5. Metal screen consists of two copper tapes or copper foil.

6. Sheath is made of flame-resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation.
– For cable lines bunched installation in cable structures, if there is no mechanical damage risk.

Cables are flame-retardant if bunched.

 N2XHBH 0,66; 1 kV, NA2XHBH 0,66; 1 kV

N2XHBH 0,66; 1 kV

Power cables with copper conductors, XLPE-insulated, armored, PE-jacketed.

NA2XHBH 0,66; 1 kV

Power cables with aluminum conductors, XLPE-insulated, armored, PE-jacketed.

Construction:

1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound.

5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

6. Jacket is made of polyethylene.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in ground (trenches) irrespective of soil and soil waters corrosiveness, except for heaving and collapsible soil, and for installation in soil with high humidity and in water.

 N2XHBH 0,66; 1 kV, NA2XHBH 0,66; 1 kV

N2XHBH 0,66; 1 kV

Power cables with copper conductors, XLPE-insulated, armored, PE-jacketed.

NA2XHBH 0,66; 1 kV

Power cables with aluminum conductors, XLPE-insulated, armored, PE-jacketed.

Construction:

1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound.

5. Screen consists of copper tapes or copper foil.

6. Separating layer is made of PVC tapes.

7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

8. Jacket is made of polyethylene.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches) irrespective of soil and soil waters corrosiveness, except for heaving and collapsible soil, and for installation in soil with high humidity and in water.

 N2XHBH 0,66; 1kV, NA2XHBH 0,66; 1kV

N2XHBH 0,66; 1kV

Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.

NA2XHBH 0,66; 1kV

Power cables with aluminum conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.

Construction:

1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.

2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).

3. Twist - insulated cable conductors are twisted.

4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant unvulcanized rubber compound.

5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.

6. Jacket is made of flame-resistant PVC compound.

Application:

– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 kV and 1 kV with frequency of 50 Hz in isolated- or grounded-neutral systems.
– For installation in ground (trenches, except for heaving and collapsible soil) and installation of single cable lines in cable structures.
– For cable lines bunched installation in cable structures and spaces.

 

Contacts:

32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales  department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
www.tatcable.ru

 

Обособленное подразделение г. Москва

Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Тел: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru

 

Page:
1 2 3 next ->
All