XLPE insulated insulated power cables for stationary laying up to 3 kV inclusively
N2XSY 0,66; 1kV
Power cables with copper conductors, insulated by XLPE, sheathed by PVC with low flammability
NA2XSY 0,66; 1kV
Power cables with aluminum conductors, insulated by XLPE, sheathed by PVC with low flammability.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).
4. Inner sheath is made of flame-resistant unvulcanized rubber compound.
5. Outer sheath is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation. For power supply to electric plants which need cable glands at bushing.
– For cable lines bunched installation in cable structures, if there is no mechanical damage risk.
N2XSY 3kV
Power cables with copper conductors, insulated by XLPE, sheathed by PVC with low flammability
NA2XSY 3kV
Power cables with aluminum conductors, insulated by XLPE, sheathed by PVC with low flammability.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant unvulcanized rubber compound.
5. Metal screen consists of two copper tapes or copper foil.
6. Sheath is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in dry and damp production spaces, on special cable racks, in blocks and for outdoor installation.
– For cable lines bunched installation in cable structures, if there is no mechanical damage risk.
Cables are flame-retardant if bunched.
N2XHBH 0,66; 1 kV
Power cables with copper conductors, XLPE-insulated, armored, PE-jacketed.
NA2XHBH 0,66; 1 kV
Power cables with aluminum conductors, XLPE-insulated, armored, PE-jacketed.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound.
5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
6. Jacket is made of polyethylene.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For installation in ground (trenches) irrespective of soil and soil waters corrosiveness, except for heaving and collapsible soil, and for installation in soil with high humidity and in water.
N2XHBH 0,66; 1 kV
Power cables with copper conductors, XLPE-insulated, armored, PE-jacketed.
NA2XHBH 0,66; 1 kV
Power cables with aluminum conductors, XLPE-insulated, armored, PE-jacketed.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with unvulcanized rubber compound.
5. Screen consists of copper tapes or copper foil.
6. Separating layer is made of PVC tapes.
7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
8. Jacket is made of polyethylene.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches) irrespective of soil and soil waters corrosiveness, except for heaving and collapsible soil, and for installation in soil with high humidity and in water.
N2XHBH 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
NA2XHBH 0,66; 1kV
Power cables with aluminum conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant unvulcanized rubber compound.
5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
6. Jacket is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 kV and 1 kV with frequency of 50 Hz in isolated- or grounded-neutral systems.
– For installation in ground (trenches, except for heaving and collapsible soil) and installation of single cable lines in cable structures.
– For cable lines bunched installation in cable structures and spaces.
Contacts:
32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
www.tatcable.ru
Обособленное подразделение г. Москва
Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Тел: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru
N2XHBH 3kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
NA2XHBH 3kV
Power cables with aluminum conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant unvulcanized rubber compound.
5. Screen consists of copper tapes or copper foil.
6. Separating layer is made of PVC tapes.
7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
8. Jacket is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches, except for heaving and collapsible soil) and installation of single cable lines in cable structures.
– For cable lines bunched installation in cable structures and spaces.
N2XSY 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low fire hazard.
NA2XSEY 0,66; 1kV
Power cables with aluminum conductors, XLPE-insulated, armored, jacketed by PVC with low fire hazard.
Construction:
1. Current-carrying conductor is made of copper (NYCY) or aluminum (NAYCY), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).
4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors.
5. Outer sheath is made of flame-resistant PVC composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 660 V and 1000 V with frequency of 50 Hz.
– For industrial purposes when delivered to domestic market and for export.
– For operation in cable structures and spaces.
N2XSY 3kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low fire hazard.
NA2XSEY 3kV
Power cables with aluminum conductors, XLPE-insulated, armored, jacketed by PVC with low fire hazard.
Construction:
1. Current-carrying conductor is made of copper (NYCY) or aluminum (NAYCY), solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated conductors of two-, three- four-, five conductor cables are twisted; two-, three- and five conductor cables have uniform conductors; four conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).
4. Inner extruded sheath is overlaid upon twisted insulated conductors and is made of flame-resistant PVC composition that fills gaps between conductors.
5. Metal screen consists of two copper tapes or copper foil.
6. Outer sheath is made of flame-resistant PVC composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For industrial purposes when delivered to domestic market and for export.
– For operation in cable structures and spaces.
N2XHBH 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
NA2XHBH 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant PVC compound.
5. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
6. Jacket is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches, except for heaving and collapsible soil) and installation of single cable lines in cable structures.
– For cable lines bunched installation in cable structures and spaces.
N2XHBH 3kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability.
NA2XHBH 3kV
Power cables with copper conductors, XLPE-insulated, armored, jacketed by PVC with low flammability
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated cable conductors are twisted.
4. Inner sheath is moulded out with filling of gaps between conductors with flame resistant PVC compound.
5. Screen consists of copper tapes or copper foil.
6. Separating layer is made of PVC tapes.
7. Armor is made of two steel tapes overlaid in such a way that the top tape covers gaps between lays of the bottom tape. For single core cables armor is made of aluminum alloy tapes.
8. Jacket is made of flame-resistant PVC compound.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of 50 Hz.
– For installation in ground (trenches, except for heaving and collapsible soil) and installation of single cable lines in cable structures.
– For cable lines bunched installation in cable structures and spaces.
Contacts:
32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
Обособленное подразделение г. Москва
Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Tel: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru
N2XS(F)2Y 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, sheathed by polymer composition, halogen-free.
NA2XS(F)2Y 0,66; 1kV
Power cables with aluminum conductors, XLPE-insulated, sheathed by polymer composition, halogen-free.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).
4. Inner sheath is made of halogen-free polymer composition.
5. Outer sheath is made of halogen-free polymer composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 and 1 kV with frequency of up to 100 Hz, including for operation in NPS systems class 3Н.
– For installation in premises and cable structures if there is no mechanical damage risk during operation.
– For installation in production and office spaces equipped with computers and other microprocessor engineering, in underground structures, residential and public buildings (cinemas, medical and educational institutions, shops).
N2XS(F)2Y 3kV
Power cables with copper conductors, XLPE-insulated, sheathed by polymer composition, halogen-free.
NA2XS(F)2Y 3kV
Power cables with aluminum conductors, XLPE-insulated, sheathed by polymer composition, halogen-free.
Construction:
1. Current-carrying conductor is made of copper or aluminum, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
3. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted; two conductor cables have uniform conductors; three-, four- and five conductor cables have all uniform conductors or one conductor of lesser section (grounding or neutral conductor).
4. Inner sheath is made of halogen-free polymer composition.
5. Metal screen consists of two copper tapes or copper foil.
6. Outer sheath is made of halogen-free polymer composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of up to 100 Hz, including for operation in NPS systems class 3Н.
– For installation in premises and cable structures if there is no mechanical damage risk during operation.
– For installation in production and office spaces equipped with computers and other microprocessor engineering, in underground structures, residential and public buildings (cinemas, medical and educational institutions, shops).
N2XS(F)2Y 0,66; 1kV
Power cables with copper conductors, XLPE-insulated, sheathed by polymer composition, halogen-free, fire-resistant.
Construction:
1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Thermal barrier is a lapping made of two micaceous tapes.
3. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).
5. Inner sheath is made of halogen-free polymer composition.
6. Outer sheath is made of halogen-free polymer composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 0.66 kV and 1 kV with frequency of up to 100 Hz.
– For industrial purposes and nuclear power stations (NPS) in NPS class 2.
– For installation in premises and cable structures if there is no mechanical damage risk during operation.
– For electrical circuits which can operate in fire conditions.
Cables are designed for bunched installation.
N2XS(F)2Y 3kV
Power cables with copper conductors, XLPE-insulated, sheathed by polymer composition, halogen-free, fire-resistant.
Construction:
1. Current-carrying conductor is made of copper, solid or stranded conductor, round- or sector-shaped, of class 1 or 2 as per GOST 22483.
2. Thermal barrier is a lapping made of two micaceous tapes.
3. Insulation is made of silane cross-linked polyethylene. Insulated conductors of multi-conductor cables have distinctive color. Insulation of neutral conductors is performed in blue color. Insulation of grounding conductors is performed in two colors (green and yellow).
4. Twist - insulated conductors of two-, three-, four- and five conductor cables are twisted. All conductors of the cable must be uniform. It is allowed to perform four conductor cables with one conductor of lesser section (grounding or neutral conductor).
5. Inner sheath is made of halogen-free polymer composition.
6. Metal screen consists of two copper tapes or copper foil.
7. Outer sheath is made of halogen-free polymer composition.
Application:
– For power transmission and distribution in fixed plants for rated alternating voltage of 3 kV with frequency of up to 100 Hz.
– For industrial purposes and nuclear power stations (NPS) in NPS class 2.
– For installation in premises and cable structures if there is no mechanical damage risk during operation.
– For electrical circuits which can operate in fire conditions.
Cables are designed for bunched installation.
Contacts:
32 Leskhozovskaya St, Stolbishche village,
Laishevo district, Republic of Tatarstan, 422624
Sales department:
Tel.: (843) 227-51-62, 227-50-21, 227-51-89
Fax: (843) 227-50-21
Information center:
8-800-200-96-97
E-mail:tatkabel@inventunion.ru
Обособленное подразделение г. Москва
Дербеневская набережная, 7
Деловой квартал "Новоспасский двор"
Стр. 22, офис № 202
Tel: (495) 775 4436, 274 0195
E-mail: tk-mostrade@inventunion.ru